


Waters is renowned for its wide range of high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) columns, offering advanced solutions for various analytical applications.
These liquid chromatography columns, along with other chromatography columns, are designed to deliver superior separation, retention, and peak resolution for a wide range of applications across industries, including pharmaceuticals, environmental testing, food safety, and biotechnology.
Each Waters column is engineered with precision to ensure consistent performance, high reproducibility, and compatibility with different chromatography systems, making them essential components for any laboratory that relies on accurate and efficient separations.
Explore Waters LC Column Technologies

ACQUITY UPLC Columns
ACQUITY UPLC columns are specifically designed for ultra-performance liquid chromatography systems, such as the ACQUITY UPLC and ACQUITY Arc systems. These columns utilize smaller particle sizes, typically less than 2 μm, which provide enhanced resolution, faster run times, and greater sensitivity. By minimizing band broadening and reducing analyte diffusion, these columns deliver sharper peaks and higher throughput, making them ideal for high-resolution separations and high-throughput labs. ACQUITY UPLC columns are widely used in pharmaceutical analysis, food testing, and environmental research, where precise and fast separations are critical.
Applications
Representative performance of glycan BEH Amide chemistry from the first injection
ACQUITY Premier Glycan BEH Amide Columns with MaxPeak High Performance Surfaces (HPS) Technology reduce sample loss caused by non-specific adsorption on metal surfaces and deliver the representative performance of Glycan BEH Amide chemistry from the first injection. ACQUITY Premier Glycan BEH Amide Columns require no conditioning or passivation, saving time and reagents, and improve recovery of the phosphorylated glycans.
Explore ACQUITY Premier Glycan BEH Amide Columns
Supreme resolution of charged glycan species

Analyzing acidic glycans is often challenging as they are frequently lost to metallic column surfaces. The ACQUITY Premier Glycan BEH C18 AX Column hardware is outfitted with specialized inert surfaces, MaxPeak High Performance Surfaces. This introduces a barrier layer to prevent acidic glycans from undergoing undesired secondary interactions inside the column. In turn, glycan recoveries are improved, and requirements for sample conditioning upon first time use is eliminated.
Providing an orthogonal technology to HILIC, the ACQUITY Premier Glycan BEH C18 AX Columns are anion-exchange reversed-phase (RP) columns that provide charge-based separations and extra resolution for acidic glycans.
With the mixed-mode separation, glycans are grouped by different charged states, and retention is increased to analyte net charge. Additional resolution of isomeric glycan species within the same charged group can be achieved due to the RP properties of the stationary phase.
Reproducibly generate the highest quality reversed-phase peptide separations

ACQUITY Premier Peptide Columns are designed to increase analyte recovery, sensitivity, and reproducibility by minimizing analyte/surface interactions that can lead to sample loss. Each batch of peptide particle material is chromatographically tested with digested peptides as part of the peptide mapping qualification.
Address the complexity of SEC separations

Experience the advancements in SEC-based technologies to address non-desired specific ionic and hydrophobic interactions for more reliable results with ACQUITY Premier Protein SEC and XBridge Premier Protein SEC Columns and Guards, which are part of the MaxPeak Premier SEC Column family.
With MaxPeak Premier SEC Columns, you can:
- Reproducibly resolve injected sample components that are less than 2x different in size for challenging applications
- Use a ‘platform SEC method’ to reduce method development time and cost
- Ensure batch-to-batch and column-to-column performance
Ruggedness you want, the repeatability you need

ACQUITY Premier Oligonucleotide Columns provide superior analyte peak shape, efficiency, and chemical stability for your oligo separations. ACQUITY Premier Oligonucleotide Columns are packed with BEH particle technology and able to operate at an elevated pH – ideal for oligo separations. The MaxPeak HPS Technology in ACQUITY Premier Oligonucleotide Columns improves the peak shape for oligos, making it easier to identify and quantify these analytes.
- Method Scaling from UPLC to HPLC Using 3 mm ID MaxPeak Premier Columns (2026)
- Efficient Method Development for Charged Aerosol Detection of Non-chromophoric Ursodeoxycholic Acid and Related Substances (2026)
- Forced Degradation Method Development for Oncologic Drug Daraxonrasib Using a Systematic Approach and MaxPeak Premier Columns (2026)
- Improving Efficiency in the Determination of PFAS in Foods of Animal Origin (2026)
- RPLC/HILIC Orthogonal Impurity Profiling of Glucagon-like Peptide-1 (GLP-1) Analogs Using LC-UV/MS Workflows (2026)

Atlantis Columns
Atlantis columns are specifically engineered for the separation of polar compounds, which are typically difficult to retain and separate using traditional reversed-phase columns. With options for both reversed-phase and hydrophilic interaction chromatography (HILIC), Atlantis columns provide excellent polar compound retention and resolution. They are available in different chemistries, including T3, dC18, and unbonded HILIC, to accommodate a wide range of analytes and separation techniques. The superior retention capabilities of Atlantis columns make them ideal for pharmaceutical and bioanalytical research, where polar compound analysis is often required.
Applications
Superior batch-to-batch reproducibility
The surface modification of Waters Atlantis Premier BEH C18 AX Columns involves separate steps to incorporate the charge modifier, the C18 groups and the endcap. This approach provides excellent control of the surface chemistry, resulting in high batch-to-batch reproducibility.
Extended pH stability for method flexibility
Combining the base-stable BEH particle with stable bonding chemistries, the Waters Atlantis Premier BEH C18 AX Column material shows exceptional resistance to both acidic and basic mobile phases for a mixed-mode stationary phase. The extended high pH stability of Atlantis Premier BEH C18 AX Columns enables labs to use a wider range of mobile phase pH values.
Selectivity that complements traditional reversed-phase

The selectivity of the Waters Atlantis Premier BEH C18 AX stationary phase is very different from traditional C18 bonded phases like HSS T3 or the C18-bonded charged surface hybrid, or CSH. The BEH C18 AX material provides the greatest retention of the acidic compound and the least retention for the base procainamide.
- Forced Degradation Method Development for Oncologic Drug Daraxonrasib Using a Systematic Approach and MaxPeak Premier Columns (2026)
- Improving Efficiency in the Determination of PFAS in Foods of Animal Origin (2026)
- Reducing Risk in Cleaning Validation and Cleaning Verification Workflows by Implementation of Mass Detection (2026)
- Flame Grilled and Fluorinated – PFAS Analysis in Barbeque Foods Using a Miniaturized QuEChERS Workflow (2026)
- Analysis of Creatine and Creatinine in Dietary Supplements Using HILIC-MS (2026)

XSelect Columns
XSelect columns offer flexibility and performance across various applications, providing a broad range of column chemistries. These columns are designed for method development, allowing analysts to explore different retention characteristics, selectivity, and peak shape optimizations. With XSelect columns, you can choose between CSH (Charged Surface Hybrid) and HSS (High Strength Silica) particles, each offering distinct advantages depending on the separation needs. XSelect columns are commonly used in pharmaceutical research and other fields that require precise method development and optimization for complex separations.
Applications
- Enabling Reliable Heparin Sodium Nucleotidic Impurity Analysis with the Alliance™ iS Bio HPLC System with PDA Detector (2026)
- Improving Analytical Greenness and Analyte Recovery of HPLC Analyses Using 3 mm ID MaxPeak™ Premier Columns (2026)
- Predictable Isolation of Radioligand Therapy Precursor PSMA-617 and Closely Eluting Impurities from a Forced Degradation Study Using a MaxPeak™ Premier OBD™ Preparative Column (2026)
- Purification of Chicoric Acid from Echinacea Tea Using a Waters MaxPeak™ Premier OBD™ Preparative Column (2026)
- HPLC Analysis of Phosphorylated Peptides on the Alliance™ iS Bio System with MaxPeak™ High Performance Surface (HPS) Technology – A System Designed for Bioseparations (2026)

CORTECS Columns
CORTECS columns utilize solid-core particle technology to offer high-efficiency separations with low backpressure. This makes them suitable for both high-performance and ultra-performance liquid chromatography applications. CORTECS columns provide a balance between performance and pressure, making them ideal for labs looking to enhance throughput without compromising resolution. They are available in C18, C8, and HILIC chemistries, offering flexibility for a range of applications.


Applications
- A Sensitive and Cost-Effective LC–MS Method for Quantifying N-Nitroso-Atenolol in Drug Formulation (2025)
- Improving Sample Throughput of HPLC Methods Using CORTECS 5 µm Columns (2025)
- Improving the Analysis of Betamethasone and Its Phosphate, Acetate, and Dipropionate Derivatives Using CORTECS™ Premier C8 Columns (2025)
- Comparing Column Lifetime of MaxPeak™ Premier Columns and Standard Hardware Columns (2025)
- Parallel Column Regeneration for Increased Analytical Throughput of Serum Steroid Hormones in Clinical Research (2024)

